1 General information
Applied symbols
SMGB0137 rev.0 - 05/2021
3
1
1.2 Applied symbols
Duringnormalheatpumpsystemdesignworkorunitinstallation,greaterattentionmustbepaidincertainsituations
requiringparticularcareinordertoavoiddamagetotheunit,theinstallationorthebuildingorproperty.
Situationsthatposearisktothesafetyofthoseinthesurroundingareaortotheunititselfareclearlyindicatedinthis
manual.
Aseriesofspecialsymbolsareusedtoclearlyidentifythesesituations.
Paycloseattentiontothesesymbolsandtothemessagesfollowingthem,asyoursafetyandthatofothersdependsonit.
! DANGER
• Thetextfollowingthissymbolcontainsinformationandinstructionsrelatingdirectlytoyoursafety,inadditiontohazards
orunsafepracticeswhichcouldresultinseverepersonalinjuriesordeath.
• Nottakingtheseinstructionsintoaccountcouldleadtoserious,veryseriousorevenfatalinjuriestoyouandothersinthe
proximitiesoftheunit.
Inthetextsfollowingthedangersymbolyoucanalsondinformationonsafeproceduresduringunitinstallation.
! CAUTION
• Thetextfollowingthissymbolcontainsinformationandinstructionsrelatingdirectlytoyoursafety,inadditiontohazardsorunsafe
practiceswhichcouldresultinminorpersonalinjuryorproductorpropertydamage
• Nottakingtheseinstructionsintoaccountcouldleadtominorinjuriestoyouandothersintheproximitiesoftheunit.
• Nottakingtheseinstructionsintoaccountcouldleadtounitdamage.
Inthetextsfollowingthecautionsymbolyoucanalsondinformationonsafeproceduresduringunitinstallation.
? NOTE
• Thetextfollowingthissymbolcontainsinformationorinstructionsthatmaybeofuseorthatrequireamorethoroughexplanation.
• Instructionsregardinginspectionstobemadeonunitpartsorsystemsmayalsobeincluded.
1.3 Norms and Regulations
FollowingRegulationEUNº517/2014onCertainFluorinatedGreenhousegases,itismandatorytollinthelabel
attachedtotheunitwiththetotalamountofrefrigerantchargedontheinstallation.
DonotventR32intotheatmosphere:R32isuorinatedgreenhousegascoveredbytheKyotoprotocolglobalwarming
potential(GWP)R32=675.
DonotventR410Aintotheatmosphere:R410AareuorinatedgreenhousegasescoveredbytheKyotoprotocolglobal
warmingpotential(GWP)R410A=2088.
TnofCO
2
equivalentofuorinatedgreenhousegasescontainediscalculatedbyindicatedGWP*TotalCharge(inkg)
indicatedintheproductlabelanddividedby1000.
Appropriaterefrigerant
Therefrigerantusedineachunitisidentiedonthespecicationlabelandmanualsoftheunit.Hitachishallnotbeheld
liableforanyfailure,trouble,malfunctionoraccidentcausedbyunitsillegallychargedwithrefrigerantsotherthanthe
speciedone.
Consequencesofchargingnon-speciedrefrigerant
Itmaycausemechanicalfailure,malfunctionandotheraccidents.
Itmaycauseoperationalfailureofprotectionandsafetydevicesofairconditioners.
Itmayalsocauselubricationfailureoftheslidingpartofthecompressorduetodeteriorationofrefrigerantoil.
Inparticular,hydrocarbonrefrigerants(suchaspropane,R441A,R443A,GF-08,etc.)arenotallowed,sincetheseare
combustibleandmaycausemajoraccidentssuchasreandexplosionincaseofimproperhandling.
Onceanon-speciedrefrigeranthasbeencharged,nofurtherservicing(includingdrainingofrefrigerant)shallbe
performed,evenincaseofmalfunction.Improperhandlingofrefrigerantmaybeacauseofreandexplosion,and
servicinginsuchcasesmaybeconsideredanillegalact.
Endclientsandcostumersshallbeinformedthatservicingisnotapproved,andtheinstallerwhochargedthe
nonspeciedrefrigerantshallbeaskedtoxtheunit.
Hitachiwillacceptnoresponsibilityforunitsthathavebeenchargedwithnon-speciedrefrigerantonce.