7 Servicing
RPK-FSR(H)M - Wall mounted
SMGB0137 rev.0 - 05/2021
246
Catches on center of bottom
side in at panel (2 portions)
Catches on
lower side
of louver (2
portions)
Front panel
Hole for catches
5 When mounting the front panel, be careful that it does not touch the horizontal louver. Paying attention to both sides
of the panel, put the catches (4 positions) on the upper side of the unit into the holes on the panel. Then push the
center of bottom side in the at panel (2 portions) and the lower side of the louver (2 positions) to fasten the catches.
? NOTE
Make sure that there is no gap nor lap between the front panel and the left side of the condensate pan. If there is a gap there, an air
leakage and dew condensation may occur and the dew may drop on the front panel.
6 Tighten 3 screws and attach 3 bushes. And then mount the air lter.
7 Insert completely the arm shafts of left and right side of the panel into the holes along the guide of the front panel.
After the at panel is attached properly, close the at panel.
Tool: Phillips Screwdriver, Slotted Screwdriver