Chapter 6 Interface with the Inverter
6 - 7
6.5 Others
6.5.1 User-defined variables "U (00)" to "U (31)" (P100 to P131)
The easy sequence function provides 32 user-defined variables "U (00)" to "U (31)", which correspond to
inverter parameters "P100" to "P131". You can use the "Data Window" of EzSQ to set data in these
variables, and store them as inverter parameters "P100" to "P131" by downloading the program
containing the variables to the inverter. After downloading the program, you can update the parameter
data by accessing parameters "P100" to "P131" from the digital operator connected to the inverter without
using EzSQ.
Function code Function name Setting Remarks
P100 to P131
User-defined
variables U
(00) to U (31)
0 to 65535 (to be defined by user)
Updateable via digital
operator or EzSQ