EasyManua.ls Logo

Hitachi UX Twin Nozzle - Page 38

Hitachi UX Twin Nozzle
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Input Register data configuration (9/9)
Word
address
Classification Item name Setting range Contents
0E F0
Various data
Current message data length 0 to 1000
Gets the message data length
(Character count x 2) of the current
message.
0E F1
Inter-character space
(Character units)
0 to 28
When Character position is
specified at Holding Register
address 0x0011, its Inter-character
space will be obtained.
0E F2 Calendar block count 0 to 8
Gets the calendar block count of
the current message.
0E F3
Calendar characters count
(Calendar block 1)
0 to 20
Gets the calendar characters
count for 8 blocks of the current
message.
0E F4
Calendar characters count
(Calendar block 2)
0 to 20
0E F9
Calendar characters count
(Calendar block 7)
0 to 20
0E FA
Calendar characters count
(Calendar block 8)
0 to 20
0E FB Time count block No. 0 to 8
Gets the time count block No. of
the current message.
0E FC Shift code block No. 0 to 8
Gets the shift code block No. of the
current message.
0E FD Shift code rule count 0 to 48
Gets the shift code rule count of
the current message.
0E FE Count block count 0 to 8
Gets the count block count of the
current message.
0E FF
Count characters count
(Count block 1)
0 to 20
Gets the count characters count
for 8 blocks of the current
message.
0F 00
Count characters count
(Count block 2)
0 to 20
0F 05
Count characters count
(Count block 7)
0 to 20
0F 06
Count characters count
(Count block 8)
0 to 20
0F 07 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
0F 0F Reserve_9
0F 10
Inter-character space
(1st digit)
0 to 28
Gets the inter-character space for
500 characters of the current
message.
0F 11
Inter-character space
(2nd digit)
0 to 28
11 02
Inter-character space
(499th digit)
0 to 28
11 03
Inter-character space
(500th digit)
0 to 28
11 04 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
12 FF Reserve_508
13 00
Printing Job
Management
(Future
subject)
Print completion count 0 to 99999 Gets the print completion count.
13 01
13 02 Print completion status 0 to 2
Gets the print completion status.
0:Non-completion
1:Print completion
2:Fault
13 03 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
13 0F Reserve_13

Other manuals for Hitachi UX Twin Nozzle