Loading...
Maximum mountable quantity
Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of
drives that can be mounted.
Component Specification
SFF 24
LFF 12
Flash module drive tray 12
Dense intermix drive tray (DB60) 60
Maximum number of flash module drives VSP N400: 192
VSP N600: 288
Maximum number of spare drives 32
Battery specifications
Storage system intake temperature CBLM
Up to 75.2º F (24º C) 5 years
Up to 86º F (30º C) 5 years
Up to 93.2º (34º C) 4 years
Up to 104º (40º C) 3 years
Host interface
Item Component Specification
Interface type Fibre Channel optical 8-Gbps, 16-Gbps, 32-Gbps
iSCSI optical 10-Gbps
iSCSI copper 10-Gbps
NAS module 10-Gbps (Fibre Channel
optical)
Data transfer speed
(maximum speed for transfer
to host)
Fibre Channel optical 800-Mbps (Fibre Channel)
1600-Mbps (Fibre Channel)
3200-Mbps (Fibre Channel)
VSP N400 and VSP N600 mechanical specifications