Item Component Specification
10-Gbps Fibre Channel
optical
12
Transferred block size 512 bytes
Maximum number of hosts
using a Fibre Channel switch
255
Maximum number of hosts
using a network switch
255
RAID specifications
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data
reliability enhanced by redundancy, there is a chance that user data could be lost due to an
unexpected host, storage system hardware, or software failure. Therefore, users are
requested to back up all data.
RAID Level SAS, SAS 7.2k, flash drives mounted
RAID 1 2D+2D, 4D+4D
RAID 5 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID 6 6D+2P, 12D+2P, 14D+2P
Item Specification
Maximum number of RAID groups VSP N400 :160
VSP N600: 240
Maximum volume size 3 TB (or 4 TB when using the LDEVs of
other storage systems)
Maximum volumes/host groups and iSCSI
targets
2048
Maximum number of volumes per RAID
group
2048
Shared memory and data assurance
VSP N400 and VSP N600 mechanical specifications
Appendix A: Mechanical specifications for VSP N400, N600
VSP N400, N600 Hardware Reference Guide 66