74
MAN0530 Issue 15 - 07/17 Searchline Excel
2104M0506
7. CERTIFICATION
HAZARDOUS AREA
TRANSMITTER/SENSOR ENTRY
SUPPLY ENTRY
SAFE AREA
OPTIONAL
CONTROL
EQUIPMENT
NOTE 1
OPTIONAL
TRANSMITTER/
SENSOR
TERMINATION UNIT
DVC100 (M) MK2
Baseefa 03ATEX0261
IECEx BAS 09.0125
ANY SUITABLE ATEX/IECEx
APPROVED SENSOR/DETECTOR
SENSOR ENTRY
SENSOR/
DETECTOR
ANY SUITABLE ATEX/IECEx
APPROVED SENSOR/DETECTOR
COMMUNICATIONS
FIXED SOCKET I.S.
OUTPUT TO CALIBRATOR
(FACTORY FITTED)
HANDHELD
CALIBRATOR
TYPE SCH 1
Baseefa03ATEX0073
IECEx BAS 09.0120
NOTES:
1. APPARATUS WHICH IS UNSPECIFIED EXCEPT THAT IT
MUST NOT BE SUPPLIED FROM, NOR CONTAIN IN NOR-
MAL OR ABNORMAL CONDITIONS, A SOURCE OF POTEN-
TIAL WITH RESPECT TO EARTH IN EXCESS OF 250V rms
OR 250V d.c.
2. INSTALL IN COMPLIANCE WITH IEC 60079-14
3. ENTRIES: ANY SUITABLY APPROVED Ex e, Ex d, IECEx e
& IECEx d CABLE GLAND/CABLE.
4. ENTRIES MUST BE SEALED TO PROVIDE A DEGREE OF
PROTECTION OF AT LEAST IP54.
5. SENSOR ENTRY: EITHER DIRECTLY CONNECTED OR
VIA SUITABLE GLAND - SEE NOTE 3.