MAN0530 Issue 15 - 07/17 Searchline Excel
2104M0506
7.2 ATEX & IECEx
7.2.1 Transmitter Details
Open-Path
Standard Junction Box
Ex e, Ex d, IECEx d
& IECEx d Certified.
M25 gland
Ex e, Ex d, IECEx d
& IECEx d Certified.
(customer supply)
Short Range Transmitter
Ex
d op is IICGb T5 (-40to+65 °C)
T6 (-40to+40 °C)
II 2G
M20 gland
Ex e, Ex d, IECEx d
& IECEx d Certified.
Flexible Conduit 900mm long
Ex e, Ex d, IECEx d & IECEx d Certified.
(seetableof Conduit Technical Characteristics)
Note: Later units
will be
1
/
2
" NPT
Short Range V max = 32 V
P max = 10 W
Mid/Long Range V max = 32 V
P max = 15 W
{
{
7.2.2 Receiver Details (for all Receivers)
Open-Path
7. CERTIFICATION
Short/Mid/Long Receiver
s
Ex
dIIC Gb T5 (-40to+65 °C)
T6 (-40to+40
°
C)
II 2G
1/2" NPT gland
Flexible Conduit 900mm long
(seetable of Conduit
Technical Characteristics)
M20 gland Ex e
(customer supply)
Certified M25
blankfitted
M20 gland
Ex e, Ex d, IECEx d
& IECEx d Certified.
Certified M20
blank fitted
IS Cable
Length 15m
max.
DVC100Termination Unit
EEx iaemIIC
T6 (-40to+65 C)
o
Vmax.=50V,
Imax.=5A
Cable glands M20/M25
SHC1 Handheld
Interrogator
Ex ia IIC
T4 (-40to+40 C)
o
Note:
Later units
1
/
2
" NPT
DVC100(M) MK2 Te rmination Unit
II 2G Ex ia e m IIC
T5 (-40 to +65°C)
V max. = 32V
Cable glands M20/M25
Short/Mid/Long
V max = 32 V
P max = 10 W
{