SCANNER AND CABLE TERMINATIONS
Scanner Pinout Connections
The 7120 scanner interfaces terminate to a 10-pin modular socket. The serial
number label indicates the interface enabled when the scanner is shipped from
the factory.
Figure 19.
MS7120-47 Keyboard Wedge
and Stand-Alone Keyboard
MS7120-41
RS232C and Light Pen Emulation
Pin
Function
Pin
Function
1
Ground
1
Ground
2
RS232 Transmit Output
2
RS232 Transmit Output
3
RS232 Receive Input
3
RS232 Receive Input
4
PC Data
4
RTS Output
5
PC Clock
5
CTS Input
6
KB Clock
6
DTR Input/LTPN Source
7
PC +5V
7
Reserved
8
KB Data
8
LTPN Data
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground
MS7120-106
RS485 and Full Speed USB
MS7120-38
RS232 Full Speed USB
Pin
Function
Pin
Function
1
Ground
1
Ground
2
RS232 Transmit Output
2
RS232 Transmit Output
3
RS232 Receive Input
3
RS232 Receive Input
4
IBM A+
4
RTS Output
5
IBM B-
5
CTS Input
6
USB D+
6
D+
7
USB +V
7
V USB
8
USB D-
8
D-
9
+5VDC
9
+5VDC
10
Shield Ground
10
Shield Ground