Accenta/Optima Engineer’s Manual
23
Flag 2
NOTE: Pressing the [9] key sets all flags ON. Pressing the [0] key sets all flags OFF. Pressing the key
leaves the function.
Accenta Optima
Version 1.00
F130-01-101
Build 101 (01)R
Date May 05 2006
System and
software version
Part No
for software
English
Version
Build
Build
Flag 2 - Options
Single Key Set
When this flag is set to ON, it allows the panel to be set by pressing . A code entry is not required.
However, a 4-digit code is required to Unset the panel. Pressing [1] toggles the flag ON or OFF.
Strobe on Set
When this flag is set to ON, the external strobe will stay on for five seconds once the panel has set. Pressing
[2] toggles the flag ON or OFF.
Flag 3
Flag 3 shows the Software Version of the panel and may be requested when contacting technical support.
Use the up arrow to scroll through the screens.
LCD keypad only: Example information you may see:
LCD Keypad:
• Press [2] to select System Flag 2. Press [1-2]
or to toggle flag on or off.
• Press or [2] to go to second option of Flag 2.
• Press to save changes and then to
leave menu or press twice to leave the menu.
LED Keypad:
• Press [2] to select of System Flag 2. Press [1-2] to toggle
flag ON or OFF.
• Press [1] and [2] to enable the first and second option of
Flag 2.
• Press to save changes and then to leave
menu or press twice to leave the menu.
System Flags (contd)
Strobe on Set
NO
[2]
or [2]
Single Key Set
Yes
System Flags
then
[2] then [1-2]
[1-2]
then
12
3
4
5
6
7
8