Accenta/Optima Engineer’s Manual
36
2 = Timed Zones
A zone programmed as Timed would be used to protect the main entry/exit door of the entry route.
LCD Keypad:
NOTE: Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as timed,
• Press to give a choice of programs or press
until P>Programs is displayed then press .
• Select program 1, 2 or 3.
• The first screen to appear is Program Edit Used Zones.
• Press [2] to enter into Timed Zones. The first zone can now be
set as timed or untimed.
• To edit the other zones press [Number] or to go to a
particular zone.
• Press three times to leave menu.
LED Keypad:
NOTE: Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as timed,
• Press to give a choice of programs. LED’s 1, 2 and 3 are
flashing.
• Select program [1, 2 or 3]. If program 1 is selected, LED 1 is ON.
• Press [2] to enter into Timed Zones. The first zone can now be
set as timed or untimed.
• To edit the other zones press [Number] to go to a particular zone.
Default settings are shown opposite.
• Press three times to leave menu.