15. Alarms Overview
The RigRat provides audible and visible alarm notification system, plus it combines local alarms on the
device with real-time remote wireless alarm notification to enhance worker safety. Local alarms include
audible buzzer alarm, visible alarm via bright LED lights, and an alarm notification on the display. The
audible alarm can be programmed or selectively turned on or off. The LED alarm indicators cannot be
turned off.
Alarm Signals
During each measurement period, the gas concentration is compared with the programmed alarm
limits for Low, High, TWA and STEL alarm. If the concentration exceeds any of the preset limits, the
alarms are activated immediately to warn of the alarm condition.
In addition, the RigRat alarms if the battery voltage is low.
When the low battery alarm occurs, it is recommended that you promptly charge the battery in a non-
hazardous location.
Alarm Signal Summary
Normal Operation Mode
Type
Red LED
Yellow LED
Green
LED
Buzzer
LCD Display
Reading
Notes
Over Range
5 beeps/s
600ms/s
"+OL"
Blink red
High
3 beeps/s
400ms/s
High alarm icon
and reading
Blink red
Low
2 beeps/s
200ms/s
Low alarm icon
and reading
Blink red
STEL
1 beep/s
200ms/s
STEL alarm icon
and reading
Blink red
TWA
1 beep/s
200ms/s
TWA alarm icon
and reading
Blink red
Unit Failure
3 beeps/s
200ms/s
Instrument fatal
error
Fail
2 beeps/s
200ms/s
"FAIL"
Blink red
Sensor generic
fail
Negative
1 beeps/s
200ms/s
"-OL"
Blink red
PID Lamp
1 beeps/s
200ms/s
"LAMP"
Blink red
PID lamp fail
Remote Alarm
1 beeps/s
200ms/s
Units in alarm in
network detail
screen
Remote device
alarm in closed
loop network,
External Alarm
1 beeps/s
200ms/s
External signal
state in
"Input/output
state" screen
4~20mA input,
digital input
Pump
1 beeps/s
200ms/s
Blink pump icon
Battery critical
1 beeps/s
200ms/s
Battery critical
icon
Battery voltage
less than 3 to
3.5V for 4s, unit
will power off in
15 minutes.