Sensor Parameters Edit Range
Parameter
Unit
Minimum
Maximum
Default
CO Span
ppm
1
500
50
CO Range
ppm
1
1000
N/A
CO Low
ppm
1
1000
35
CO High
ppm
1
1000
200
CO STEL
ppm
1
1000
100
CO TWA
ppm
1
1000
35
H
2
S Span
ppm
1
100
10
H
2
S Range
ppm
1
100
N/A
H
2
S Low
ppm
1
100
10
H
2
S High
ppm
1
100
20
H
2
S STEL
ppm
1
100
15
H
2
S TWA
ppm
1
100
10
LEL Span
%LEL
10
60
50
LEL Range
%LEL
1
100
N/A
LEL Low
%LEL
10
60
10
LEL High
%LEL
10
60
20
O
2
Span
%
1
30
18
O
2
Range
%
1
30
N/A
O
2
Low
%
1
30
19.5
O
2
High
%
1
30
23.5
HCN Span
ppm
1
50
10
HCN Range
ppm
1
50
N/A
HCN Low
ppm
1
50
4.7
HCN High
ppm
1
50
25