18 107062-12 EN FR26 GLO 501 Printed in France
Directives Compliance
Machine Directive 98/37/EC
Low Voltage Directive 73/23/EC
Electromagnetic Compatibility Directive 89/336/EC
Control Reliability
“Control Reliability” means that “the device, system or interface shall be designed, constructed and installed
such that a single component failure within the device, interface or system shall not prevent normal stopping
action from taking place but shall prevent a successive machine cycle.” (ANSI B11.19-1990, 5.5)
OSHA  29  CFR  1910.217  states  that  “the  control  system  shall  be  constructed  so  that  a  failure  within  the
system does not prevent the normal stopping action from being applied to the press when required, but does
prevent  initiation  of  a  successive  stroke  until  the  failure  is  corrected.    The  failure  shall  be  detectable  by  a
simple test, or indicated by the control system.”
Honeywell has developed new patented self-checking techniques which combine reliability with safety.  The
FF-SB Series light curtains function with dual channel redundancy and positive self-checking monitoring.  This
means that a faulty component in our system will make the safety barrier fail in a safe mode.
This design meets the highest requirements (Category 4 Electrosensitive Protective equipment) as described
in the IEC 61496 European project norm.  Category 4 safety light curtains are designed and manufactured in
such  a way  that  a  single breakdown  or  an  accumulation  of  failures  does  not  lead  to  the  loss  of the  safety
function when a dangerous situation arises.  The safety function is maintained on a permanent basis.