107062-12 EN FR26 GLO 501 Printed in France  23
Power Indicator (emitter)
FF-SB Series emitters have a yellow E1 LED that, if illuminated, indicates power is applied to the light curtain
(see figure 1-9).
Figure 1-9  Emitter Indicators
Synchronization Beam Reception Indicator (emitter)
FF-SB  Series  emitters  have  a  yellow  E2  LED  that,  if  illuminated,  indicates  the  synchronization  beam  is
established.  (see figure 1-9).  E2 also illuminates if one beam is interrupted near the emitter.
Mirrors
FF-SB Series mirrors provide a means to guard more than one side of a danger zone with one light curtain.
One or two mirrors can be used with a emitter and receiver pair.  For FF-SB12 and FF-SB14 light curtains,
each  mirror  reduces  the  scanning  range  by  10  %.    For  FF-SB15  light  curtains,  each  mirror  reduces  the
scanning range by 15 %.  See the Scanning Range with Mirrors table below.
Scanning Range with Mirrors
FF-SB Series Scanning Range m (ft) Scanning Range with Mirrors
1 Mirror 2 Mirrors
FF-SB12 10 (32.8) 9 (26.52) 8,1 (23.87)
FF-SB14 10 (32.8) 9 (26.52) 8,1 (23.87)
FF-SB15 24 (78.8) 20,4 (75) 17,3 (63.7)
E2