EasyManuals Logo

Honeywell Galaxy Flex Installer Manual

Honeywell Galaxy Flex
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Galaxy Flex Installer Manual Codes [42, Quick Menu 7]
57
1. Press #. The address of the first keypad on the system is displayed.
2. Use A or B to select the required keypad.
3. Press ent to accept the selection.
Note: The address of the keypad that is currently being used is indicated by a black square
flashing over the first digit of the keypad address.
‘Card-Held’ Operation
The programmed MAX function is activated when the card/fob /tag is held continuously in
front of the MAX/MicroMAX/KeyProx reader for 3 seconds.
If using a MAX/MicroMAX or KeyProx the reader or KeyProx must be assigned a common
group to the user. The keypad specified in option 7=MAX function displays the assigned
MAX function.
Assigning Dual Functions to MAX Numbers
If a card has a # assigned to the number, then any card-held function will only work in
conjunction with the user’s PIN, provided that the PIN has a # assigned also.
The Dual Focus function will work in either order, but if the card is presented first, the user
has PIN controlled access to the normal menu (see Codes [42] for programming).
If a user’s card number is assigned a
, then the card becomes Dual access. This means that
it will not open the door without another PIN or card (see Codes [42] for programming).
Template [42.1.User code.9]
An Access Template controls the areas to which a user has access, and also the access times.
Once a template is created in Access Template [45.6] it can be assigned to multiple users.
This eliminates repetitive programming of common door access rights for multiple users.
If no access template is allocated to a user, access rights for that user are defined by the
Groups to which the user is allocated. This means the user has access through any door
configured to a Group that is common to the user's group allocation.
Note: By assigning a template only the groups assigned in the template will control the
groups the card has access to. The groups assigned to the User Code will no longer control
access for the card.
Radio Fob [42.1.User code.10]
Use this option to register a keyfob on the system. Keyfobs can be assigned to a maximum
of 100 users (depending on the system model), and can be programmed to set/unset or
activate panic alarms, or both. These options may be limited by certain regional restrictions.
To register a keyfob:
1. Select 1=Learn Fob, and then press ent.
The serial number is shown if a fob has been programmed.
2. If you enter the serial number manually, select the device type: 1=Alpha or 2=V2.

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals