EasyManuals Logo

Honeywell Galaxy Flex Installer Manual

Honeywell Galaxy Flex
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Galaxy Flex Installer Manual Parameters [51]
83
1=No of Alarms The total number of zone activations signalled in any one set period.
The selectable values are 0 to 10 where 0 is unlimited.
2=Unset Limit The number of activations logged from any one zone in any one unset
period. The selectable values are 0 to 10 where 0 is unlimited. The
default is 3. Fire alarms are not restricted by this parameter.
3=Set Limit The number of activations logged from any one zone in any one set
period. The selectable values are 0 to 10 where 0 is unlimited. The
default is 3. Fire alarms are not restricted by this parameter.
Note: This feature only affects Contact ID, SIA and Microtech communication formats.
Confirm Time [51.49]
Use this option to set the maximum time between two separate zones for a confirmed alarm
to be generated up to a maximum of 99 minutes, which is equivalent to the complete set
period, with a default of 30 minutes.
Keypad Access [51.54]
Use this option to select how the keypad unsets the system. There are two options:
1=Always Keypad always unset the system.
2=Except Entry Except when entry time is running. This ensures that users are
unsetting using a fob or MAX tag (portable device).
Confirm Operation [51.55.1]
Use this option to control when confirmed alarms can be triggered. The choices are:
1=Before Entry Confirmed alarms can be triggered before starting entry time
only.
2=Except entry Confirmed alarms can be triggered any time except during the
entry delay period. (PD6662: 2004)
3=Always Confirmed alarms are always enabled. (PD6662: 2010)
Confirm Entry Timeout [51.55.2]
Use this option to control whether exit type zones can cause confirmed alarms after an entry
timeout.
0=Disable Exits Exit type zones will only cause unconfirmed intruder alarms. They will
not contribute to the two activations required for a confirmed alarm.
1=Enable Exits After the expiry of the entry delay, activation of an exit type zone will
be identical to an intruder zone.

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals