Granit XP User Guide 103
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology barcode
below. On the Symbology Charts on page 279, find the symbology you want to set
as high priority. Locate the Hex value for that symbology and scan the 2 digit hex
value from the Programming Chart, beginning on page 291, then Save. Default =
None.
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology barcode
below. On the Symbology Charts on page 279, find the symbology you want to set
as low priority. Locate the Hex value for that symbology and scan the 2 digit hex
value from the Programming Chart, beginning on page 291.
If you want to set additional low priority symbologies, scan FF, then scan the 2 digit
hex value from the Programming Chart, beginning on page 291, for the next sym-
bology. You can program up to 5 low priority symbologies. Scan Save to save your
selection. Default = None.
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority
symbologies, you must set the time-out period. This is the period of time the scan-
ner will search for a high priority barcode after a low priority barcode has been
encountered. Scan the barcode below, then set the delay (from 1-3,000 millisec-
onds) by scanning digits from the Programming Chart, beginning on page 291,
then Save. Default = 500 ms.
Preferred Symbology Default
Scan the barcode below to set all Preferred Symbology entries to their default val-
ues.
High Priority Symbology
Low Priority Symbology
Preferred Symbology Time-out
Preferred Symbology Default