Section 3: Programming the Communicator
3-15
PROMPTS
ZONE
TRIG.
4204/
2-4204
OPTIONS DESCRIPTION
28
Open/Close Zone
(0)_
X X
Zone Trig: [3-7]
4204: [1-4]
2-4204:
[1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports. This zone assignment must
be unique from the Telco zone selected in Prompt
27.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8
cannot be used.
NOTE: Connect an open/close (arm/disarm) trigger
(or relay output) from the control panel to the
open/close zone.
29
Zn1 Trigger Type
(V+)_
X
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
30
Restore Zn1 Y/N
(Y)_
X X
[Y], [N]
Enables restore reporting for zone 1.
31
Delay Zn1 (secs)
(00)_
X X
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 1.
32
Rpt Zn1 ONLY if
Armed (N)_
X X
[Y], [N]
Reports alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
33
Invert Zn2 Y/N
(N)_
X
[Y], [N]
Inverts the alarm and normal states of the zone 2
trigger; otherwise uses normal input signal.
34
Restore Zn2 Y/N
(Y)_
X X
[Y], [N]
Enables restore reporting for zone 2.
UL/ULC: Must be set to “Y.”
35
Delay Zn2 (secs)
(00)_
X X
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 2.
UL/ULC: Must be set to “00.”
36
Rpt Zn2 ONLY if
Armed (N)_
X X
[Y], [N]
Reports alarms on zone 2 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 2.
37
Zn3 Trigger Type
(V+)_
X
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
38
Invert Zn3 Y/N
(N)_
X
[Y], [N]
Inverts the alarm and normal states of the zone 3
trigger; otherwise uses normal input signal.
39
Restore Zn3 Y/N
(Y)_
X X
[Y], [N]
Enables restore reporting for zone 3.
UL/ULC: Must be set to “Y.”
40
Delay Zn3 (secs)
(00)
X X
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 3.
UL/ULC: Must be set to “00.”