Programmable Fields
Name The name of the area that displays when selecting a procedure.
Ambush An action that must be done in addition to the normal disarming
procedure. If this additional action is not done, the area sends a
distress signal to the I9000 Control Unit. Select from AFTER,
BEFORE, and NONE.
Amb. Del. The time limit (in seconds) allowed for performing the Ambush
action.
Master An area that controls one or more other selected area numbers.
Entry Delay The amount of time (in seconds) a person has to disarm the system
after entering an armed area.
Exit Delay The amount of time (in seconds) a person has to leave an area
after arming it.
Common The identity number of a specific area that arms and disarms
associated areas. Areas with a common identity number arm when
the last area in the group arms. These areas also disarm when the
first area in the group disarms.
Late Clo. The maximum times allowed for extending the closing time after
normal business hours. This field allows values 1 through 7. Each
time the closing alert sounds, the closing time can be extended two
hours.
Open Time The time limit (2 to 240 minutes) before a disarmed area rearms
automatically.
Disarm The number of codes or other actions required to disarm an area.
Choices are 0 codes, 1 code, 2 codes, IN+1 code, and IN+2 codes.
Clos. Alrt. A message that an area will arm within x time after the message
appears.
Account A three-digit number that identifies an area for the customer service
center if an IDC is used. (Not available with XSM system.)
ON/OFF Fields
Press the space bar to toggle each of the following fields on or off.
Enabled Select to activate an area.
Force Arm Allows the operator to arm an area when there are points in the
area in alarm.
Clos Alrt Select to activate warning sounds before an area arms.
Auto Rearm Selects to arm the area either on a schedule or with a remote
command.
Schedule Select if desired for the I9000 schedule to control area disarming.
Transm O/C Select for an area to send its opening and closing signal to the
XSM control center.