Midas
®
Gas Detector
15-3
15.5 Midas
®
Complete Gas Detector Kits
A complete kit including a universal Midas
®
transmitter (MIDAS-T-004) and a selected Midas
®
sensor
cartridge can be ordered as a combined package. Each sensor cartridge is supplied with an extended 2
year warranty. Sensor cartridge and gas detector are packaged separately for ease of installation. Note
that to detect NF
3
a separate pyrolyzer module must also be ordered.
Complete detector kit and sensor cartridge description Kit part no.
Ammonia 0-100 ppm kit MIDAS-K-NH3
Arsine 0-0.2 ppm and Germane 0-0.8 ppm kit MIDAS-K-ASH
Boron Trichloride 0-8 ppm, Dichlorosilane 0-8 ppm, Hydrogen Bromide 0-8 ppm, Hydrogen Chloride 0-8 ppm MIDAS-K-HCL
Boron Trifluoride 0-4 ppm, Hydrogen Fluoride 0-12 ppm, Nitrogen Trifluoride 0-40 ppm and Tungsten Hexafluoride 0-12 ppm kit
MIDAS-K-HFX
Bromine 0-0.4 ppm and Chlorine Dioxide 0-0.4 ppm kit MIDAS-K-BR2
C4F6 0-40ppm, C5F8 0-40ppm and CH2F2 0-240ppm (A separate pyrolyzer module, MIDAS-T-0P3, must be ordered) MIDAS-K-XCF
Chlorine 0-2 ppm and Fluorine 0-4 ppm kit MIDAS-K-HAL
Carbon Dioxide 0-2.0% v/v kit MIDAS-K-CO2
Carbon Monoxide 0-100 ppm kit MIDAS-K-COX
Diborane 0-0.4 ppm kit MIDAS-K-B2H
Hydrogen 0-1000 ppm kit MIDAS-K-H2X
Hydrogen 0-100% LEL and Methane 0-100% LEL kit
1
MIDAS-K-LEL
Hydrogen Cyanide 0-20 ppm kit MIDAS-K-HCN
Hydrogen Sulfide 0-40 ppm kit MIDAS-K-H2S
NF3 0-40ppm and CH3F 0-120ppm (A separate pyrolyzer module, MIDAS-T-0P3, must be ordered) MIDAS-K-XHF
Nitric Oxide 0-100 ppm kit MIDAS-K-NOX
Nitrogen Dioxide 0-12 ppm kit MIDAS-K-NO2
Oxygen 0-25% v/v kit MIDAS-K-O2X
Ozone 0-0.4 ppm kit MIDAS-K-O3X
Phosphine 0-1.2 ppm kit MIDAS-K-PH3
Silane 0-20 ppm and Disilane 0-20 ppm kit MIDAS-K-SHX
Silane low level 0-2 ppm kit MIDAS-K-SHL
Sulfur Dioxide 0-8 ppm kit MIDAS-K-SO2
TEOS 0-40 ppm kit MIDAS-K-TEO
1
Midas
®
detectors are not ETL approved for monitoring in or sampling from classified areas above 25% LEL

Table of Contents

Other manuals for Honeywell Midas

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Midas and is the answer not in the manual?

Honeywell Midas Specifications

General IconGeneral
Power Supply24 VDC
Detection TechnologyElectrochemical, Infrared
Sampling MethodDiffusion
DisplayLCD
CommunicationModbus RTU, 4-20mA
Operating Temperature-20°C to +50°C
Humidity Range0% to 95% RH (non-condensing)
Target GasMultiple gases
Response Time< 30 seconds
Operating Humidity0% to 95% RH (non-condensing)
Outputs4-20mA
Protection RatingIP66
CertificationsATEX, UL, CSA
Detection GasesOxygen (O2), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Methane (CH4), and others