EMM-3U UNIVERSAL ELECTRONIC MINIZONEā„¢ PANEL
3 68-0237-2
a
Heat pump thermostat with single Y first-stage terminals. See
Heat Pump Thermostats section and Fig. 6.
b
Multi-stage and heat pump thermostats are not required to
control multi-stage and heat pump systems. They are used
only when second stage or emergency heat control from the
zone thermostat is needed.
c
The Y594R1243 must be wired to the panel using the B ter-
minal for changeover.
d
Cut thermostat second-stage variable heating anticipator
wire (gray).
e
Cut thermostat first-stage fixed heating anticipator wire (bare)
and second-stage variable heating anticipator wire (gray).
f
Cut thermostat second-stage cooling anticipator wire (lowest
bare wire).
Recommended Dampers (See Table 2):
Five ZD or ARD dampers maximum connected to each panel
and a maximum of five dampers per zone.
Use SDCR for additional dampers required on one zone.
Dampers are connected to M1 Common, M4 Open, and M6
Closed (see Fig. 8-12 for hookups).
Damper Connections:
Accessories: For required accessories, see Table 3.
Table 1. Recommended Thermostats.
System Non-Programmable Programmable
Single-
Stage
T87F1859/Q539A1014
T87F4010/Q539A4026
T8501D1046
T8400C1016
T8400C1040
T8400C1099
T8501D1111
T8601D2027
T8600D2069
T8600D2028
T8601D2019
T8602D2018
T8602D2000
T8000C1002
T8000C1010
T8001C1019
PC8900/W8900A,C
Heat
Pump
b
Y594R1243
a,c,d
Y594G1252
a,e
T8411R1002
T8411R1028
T8611G2051
a
T8011R1006
T8011R1014
T8011F1002
Multi-
Stage
b
T8424D1008
T8424D1016
T8524D1007
T8524D1015
Y594D1347
f
T8524D1015
T8624D2004
T8624D2012
T8024D1002
T8024D1010
T8024F1007
Table 2. Recommended Dampers.
Honeywell Damper Type Round Rectangular
Power-open/power closed
(for systems >2000 cfm)
MARD D642 using
ML6161 Motor
Actuator
Spring-open/power-closed
(for systems </= 2000 cfm)
ARD ZD
Motor Terminal Damper Action
Common/M1 Common
Open/M4 Power Open
Closed/M6 Power Close
Table 3. Required Accessories.
Accessory Description
40 VA transformer AT140D1046
Capacity protector C7735A1000
Round static pressure
regulator damper
7 SPRD
8 SPRD
9 SPRD
10 SPRD
12 SPRD
14 SPRD
16 SPRD
300 cfm
400 cfm
600 cfm
750 cfm
1200 cfm
1800 cfm
2400 cfm
Rectangular static
pressure regulator
damper
12 x 8 SPRD
12 x 10 SPRD
12 x 12 SPRD
20 x 8 SPRD
20 x 10 SPRD
20 x 12 SPRD
1000 cfm
1200 cfm
1400 cfm
1600 cfm
2000 cfm
3000 cfm