EAS System Connection
The following information should be used in conjunction with the manufacturer’s
documentation EAS system.
Checkpoint
®
EAS System Integration
Honeywell cables compatible with Checkpoint EAS systems include five
additional wires for device connection*. Consult the table below for the
appropriate wire and terminal configuration.
Antenna and Interlock
Connection
Cable
(MX-5S236-E-3 or MX-5S114-E-3)
Checkpoint Device
Wire Color Wire Gauge Connection Type
Solid Light Green Thin INTLK + Terminal
Interlock
Solid Black Thin INTLK - Terminal, GND
Red and White Thick Antenna + Terminal
Antenna
Black and White Thick Antenna - Terminal
No Insulation/Shield Antenna Shield
Interlock functionality requires specific EAS device settings. Consult the
manufacturer’s EAS system documentation for the appropriate switch and timing
potentiometer settings.
* Caution Statements
For North America:
Caution: To maintain compliance with applicable standards, all circuits
connected to the scanner must meet the requirements of a NEC
Class 2 power source or Limited Power Source as defined in UL
60950-1 2nd edition Clause 2.5.
For Other Countries:
Caution: To maintain compliance with applicable standards, all circuits
connected to the scanner must meet the requirements of a Limited
Power Source as defined in IEC 60950-1 2nd edition Clause 2.5.