46
Imager Pinouts–MS7580-124-EAS
Figure 29. MS7580-124-EAS, 10-Pin Female Modular Socket
RS232
USB

Pin Function Pin Function
1
Signal/Power Ground
1
Signal/Power Ground
2
CTS Input
2
Tied to Pin 4 in Cable
3 RS232 Receive Input 3 No Connect
4 No Connect 4 Tied to Pin 2 in Cable
5 Reserved 5 Reserved
6 RTS Output
6 USB D+
7
Reserved
7
+5VDC USB Power
8
RS232 Transmit Output
8
USB D-
9
+12V Power
9
+12V Power
10
Shield Ground
10
Shield Ground
SHELL
Signal/Power Ground
SHELL
Signal/Power Ground
Integrated RF EAS Antenna
(MS7580-124-EAS Models Only)
Figure 30. 2-Pin Box Receptacle
Pin Function
1
EAS ANT -
2 EAS ANT +
USB requires 12V power for pass-through functionality.
Signals on Pin 6 and 8 are TTL full level RS232 output signals on MS7580-124-EAS