QUESTION 16 DISPLAY OPTIONS
L1 L2 L3 L4
This question defines display options. Enter the digits as follows:
Q 16, L1 – Enter the L1 digit from the table below.
L1
Entry
Armed Bypass
Display
Display Fault
On Entry
No AC Loss
Display
Manual
Bypass Limit 3
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔ ✔
6
✔ ✔
7
✔ ✔ ✔
8
✔
9
✔ ✔
A
✔ ✔
B
✔ ✔ ✔
C
✔ ✔
Armed Bypass Display: If
selected, pressing the [BYPASS]
key will scroll bypassed zones
while the system is armed.
Display Fault on Entry: Display
faults (open zones) during entry
delay time.
No AC Loss Display: If selected,
the AC loss message will not be
displayed on LCD keypads.
Manual Bypass Limit 3: If
selected, no more than 3 zones can
be manually bypassed.
D
✔ ✔ ✔
E
✔ ✔ ✔
F
✔ ✔ ✔ ✔
U
L
Do not enable No AC Loss
Display (must display AC
loss) for UL installations.
Q 16, L2 – Enter the L2 digit from the table below.
L2
Entry
No
Code
Set
Time
Daylight
Saving
(Summer)
Time
Keypad
Extinguish
Keyfob
Low
Bat.
Display
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔ ✔
6
✔ ✔
7
✔ ✔ ✔
8
✔
9
✔ ✔
A
✔ ✔
B
✔ ✔ ✔
C
✔ ✔
D
✔ ✔ ✔
E
✔ ✔ ✔
F
✔ ✔ ✔ ✔
No Code Set Time: If selected, allows Quick
Command #3 to set time. Intended for low-security
installations.
Daylight Saving (Summer) Time: If selected,
the system will automatically adjust for daylight
saving (summer) time (U.S. standard: First
Sunday in April at 2:00 AM, the clock goes ahead 1
hour; last Sunday in October at 2:00 AM, the clock
goes back 1 hour to standard time).
Keypad Extinguish: If selected, the keypad
display and LEDs will turn off after 1 minute of no
key presses.
Keyfob Low-Battery Display: This option
determines whether low-battery messages from
keyfobs will be displayed. If selected, display is
enabled. Note that even if this display is disabled,
keyfob low-battery conditions can be checked by
using the #56 Quick Command.