Pallet Accuglide ZoneFlex Accumulation Conveyor | Maintenance Manual | 29334206 45
February 14, 2018
Service and Repair
Adjusting the Driver Pad Length
Use the procedure below to adjust the driver pad length.
1. Turn off and lockout/tagout all power to the conveyor section.
2. Select the location where the driver pad is to be cut. Make sure the location is at
least 12 inches from the chain connecting link.
3. On either side of the splice,
a. make a square cut 19/32 inch from the centerline of the chain pin hole. See
illustration Cutting and Re-splicing the Driver Pad
b. chamfer the edges 1/8 inch at a 45° angle
4. Make a splice connection by inserting a 7/8-inch long piece of 1/4-inch OD air hose
tubing into both ends of the driver pad.
5. Firmly push the pad (and splice connection) onto the chain pins.
6. Install the carrier rollers.
7. Remove lockout/tagout and restore power to the conveyor section.
8. Make sure the driver chain and driver pad are operating correctly.