25 RMA803 Remote Indicator User's Guide Revision 2
4.5 Monitoring the Standard Display
Table 8: Standard Display with PV Format Display Indications
Display Messages What It Means
Diagnostic Messages
These messages are
displayed in the lower
line right justification of
the screen when the
diagnostic conditions
are present in the
Transmitter and
Remote Indicator.
BAD-Tx Transmitter critical diagnostic condition present
This message is displayed any time a critical diagnostic is present in the
transmitter. If a critical diagnostic is present, the message “BAD-Tx” will
display at the bottom line of the screen and the Last known good value will
be flash at the top line of the screen.
BAD-RMA RMA diagnostics present
This message is displayed any time RMA diagnostic are present. If RMA
diagnostics are present, the message “BAD-RMA” will display at the
bottom line of the screen and the last known good value will be flash at
the top line of the screen.