VISIONPRO
®
8000 WITH WI-FI
®
35 33-00096—01
1014 Vent During Hum
or Dehum Calls
Yes
No
Yes Both This feature is used to help reach the user's
desired humidity level by not allowing the
ventilation equipment to run during a call for
humidification or dehumidification.
Yes: Ventilation is allowed to run during a call
for humidification or dehumidification.
No: Ventilation is NOT allowed to run during a
call for humidification or dehumidification.
1016 Vent On High
Indoor Humidity
Off
On
On Both This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV.
Off: The humidity level has no effect on
ventilation.
On: The thermostat removes excess humidity
by turning on the ventilator when the indoor
humidity rises 10% above the user's
humidification setting. The thermostat must be
in the heat mode to ventilate on high humidity.
1017 Ventilator Core
Reminder
Off
3, 6, 9, 12 Calendar Months
Off Both Ventilator Core Cleaning Reminder
1017 Ventilator Filter
Reminder
Off
3, 6, 9, 12 Calendar Months
Off Both Ventilator Filter Cleaning Reminder
1100 Number of UV
Devices
0, 1, 2
0 Both Press the up/down arrows to select the number
of UV devices installed in the system. Some
systems may have two UV devices, one for the
A-Coil and another for Air Treatment. A
replacement reminder can be setup for each
one. Select 0 if no UV devices are installed.
1105 UV Bulb 1
Reminder
Note: “1” is not
displayed if there
is only 1 UV Bulb
Off, 6, 12, 24 Calendar Months
Off Both UV Bulb 1 Replacement Reminder
1105 UV Bulb 2
Reminder
Off, 6, 12, 24 Calendar Months
Off Both UV Bulb 2 Replacement Reminder
1200 Custom
Reminders
View / Edit Custom Reminders
Add Custom Reminders
None Both See “Customizable Reminders” beginning on
page 73.
28 Backlighting
On Demand
Continuous
On Demand Both Select Continuous or On Demand backlighting.
Select Continuous backlighting if you would like
the backlight to be on all the time.
Select On Demand backlighting if you would like
the backlight to only turn on after a key press.
After you complete your changes, the screen
stays lit for 45 seconds.
1400 Clock Format
12 hour
24 hour
12 Both
1401 Daylight Saving
Time
Off
On
On Both Set to Off in areas that do not follow Daylight
Saving Time.
Table 2. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name Settings Default
Residential,
Commercial
or Both Notes