6 - 33
Telepen
<Default All Telepen Settings>
Telepen On/Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pat-
tern 1 and decodes them as standard full ASCII (start/stop pattern 1).  
When Original Telepen Output is selected, the scanner reads symbols with 
start/stop pattern 1 and decodes them as compressed numeric with 
optional full ASCII (start/stop pattern 2).  
Default = AIM Telepen Output.
Telepen Redundancy
If you are encountering errors when reading Telepen bar codes, you may 
want to adjust the redundancy count.  Redundancy adjusts the number of 
times a bar code is decoded before transmission, which may reduce the 
number of errors.  Note that the higher the redundancy count, the longer it 
will take to decode the bar code.  To adjust the redundancy, scan the 
Original Telepen Output
*  AIM Telepen Output