EasyManua.ls Logo

HORNER XL4 - HSC Period Measurement Mode

HORNER XL4
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAN0964-14-EN_XL4_XL4P_UM
N o v e m b e r 1 0 , 2 0 2 1 P a g e 92 | 194
9.3.4 Period Measurement
In period measurement mode, the high-speed input can measure the period of a pulse stream
in one of two modes and provides a continuous indication of the last sampled value. In this
mode, the Disable and Latch special functions are allowed. Refer to the HSC Glossary for a
description of these functions.
Period Rising Edges 1 μs Counts In this sub-mode the period of the input signal is reported in
one (1) μs units. The period measurement will start on the rising edge of the input.
Period Falling Edges 1 μs Counts In this sub-mode the period of the input signal is reported in
1 μs units. The period measurement will start on the falling edge of the input.
Figures 9.3-9.4 Period Measurement, Rising Edges & Falling Edges
Period from Rising Edge
Period from Falling Edge

Table of Contents

Related product manuals