162
[PE1] display interface tunnel 1
Tunnel1 current state: UP
Line protocol current state: UP
Description: Tunnel1 Interface
The Maximum Transmit Unit is 1500
Internet Address is 12.1.1.1/24 Primary
Encapsulation is TUNNEL, service-loopback-group ID not set
Tunnel source unknown, destination 3.3.3.3
Tunnel protocol/transport CR_LSP
Output queue : (Urgent queuing : Size/Length/Discards) 0/100/0
Output queue : (Protocol queuing : Size/Length/Discards) 0/500/0
Output queue : (FIFO queuing : Size/Length/Discards) 0/75/0
Last 300 seconds input: 5 bytes/sec, 0 packets/sec
Last 300 seconds output: 5 bytes/sec, 0 packets/sec
34 packets input, 2856 bytes
0 input error
34 packets output, 2856 bytes
0 output error
The output shows that traffic is forwarded along the CR-LSP of the TE tunnel.
Troubleshooting MPLS TE
This section describes how to troubleshoot MPLS TE.
No TE LSA generated
Symptom
OSPF TE is configured but no TE LSAs can be generated to describe MPLS TE attributes.
Analysis
For TE LSAs to be generated, at least one OSPF neighbor must reach the FULL state.
Solution
1. Execute the display current-configuration command to verify that MPLS TE is configured on
involved interfaces.
2. Execute the debugging ospf mpls-te command to observe whether OSPF can receive the TE LINK
establishment message.
3. Execute the display ospf peer command to verify that OSPF neighbors are established correctly.

Table of Contents

Other manuals for HP 10500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 10500 series and is the answer not in the manual?

HP 10500 series Specifications

General IconGeneral
BrandHP
Model10500 series
CategorySwitch
LanguageEnglish

Related product manuals