HP Array Configuration Utility 70
MSA1000 at Lab 4
Adapter ID: 210000E08B07A68F
connectionname: Unknown
Location: Local
Status: Online
Host Mode: Default
logicaldrive 1 is unmasked
Adapter ID: 5034414235583942
connectionname: Unknown
Location: Unknown
Status: Offline
Host Mode: Default
logicaldrive 1 is masked
Modifying connection names
You can convert a lengthy adapter ID into a brief connection name that can be used in all future
commands.
Syntax:
<target> modify ai=# cn="connection name"
where <target> is a controller that supports SSP.
Example command:
ctrl ch="Lab 4" ld 1 modify ai=210000E08B07A68F cn="cnxn 3"
Managing host modes (connection profiles)
Syntax:
<target> modify ai=# hostmode="operating system type"|?
where <target> is a controller that supports host modes.
Example command:
=> ctrl ch="Lab 3" modify ai=5034414235583942 hostmode=?
NOTE: The connection name and the logical unit are required for managing host modes.