EasyManua.ls Logo

HP 166207-B21 - Smart Array 5302/32 RAID Controller - Raid 1+0 (Raid 10)

HP 166207-B21 - Smart Array 5302/32 RAID Controller
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive arrays and fault-tolerance methods 98
RAID 1+0 (RAID 10)
In a RAID 1+0 (RAID 10) configuration, data is duplicated to a second drive.
When the array has more than two physical drives, drives are mirrored in pairs.
In each mirrored pair, the physical drive that is not busy answering other requests answers any read
requests that are sent to the array. This behavior is called load balancing. If a physical drive fails, the
remaining drive in the mirrored pair can still provide all the necessary data. Several drives in the array
can fail without incurring data loss, as long as no two failed drives belong to the same mirrored pair.
This fault-tolerance method is useful when high performance and data protection are more important than
the cost of physical drives.
NOTE: When there are only two physical drives in the array, this fault-tolerance method is
often referred to as RAID 1.