HP StorageWorks 1000 Modular Smart Array installation guide 67
d. Install the HBA driver on the new kernel by entering:
./INSTALL -f
e. If not already connected, connect the MSA to the SAN.
NOTE: For Qlogic HBAs, to build an HBA driver from source code or manually patch the
Linux kernel, see the README file in the /opt/hp/src/hp_qla2x00src
directory on the
server.
7. To install the HP System Management Homepage:
NOTE: The System Management Homepage must be installed prior to the ACU.
a. Navigate to the /SMH/Linux directory on the CD.
b. List the contents of the directory and identify the installation rpm file for your environment.
c. Copy the file to a directory on the server.
d. Change to the server directory of the file and un-tar the installation file by entering:
tar -zxvf <SMH_tar_filename>
(Where <SMH_tar_filename> is the name of the System Management Homepage .zip
file.)
e. Install the System Management Homepage by entering:
rpm -ivh <SMH_rpm_filename>
(Where <SMH_rpm_filename> is the name of the System Management Homepage rpm.)
8. To install the Array Configuration Utility (ACU):
NOTE:
• You must remove earlier versions of the ACU before installing later versions.
• You must install the HP System Management Homepage before installing the ACU.
• For information about using the ACU or the ACU-CLI, see ACU online help or the ACU
section of the Configuring Arrays Reference Guide.
a. Navigate to the /ACU/Linux/x86 directory on the CD.
b. List the contents of the directory and identify the ACU installation rpm file for your
environment.
c. Install the ACU by entering:
rpm -ivh <ACU_rpm_filename>
(Where <ACU_rpm_filename> is the name of the ACU rpm.)