HP StorageWorks 1000 Modular Smart Array installation guide 75
IMPORTANT: In multipath configurations:
Verify that both HBAs in each server have been granted access to the storage.
In active/active configurations, manually assign a preferred path (controller ownership) for each
LUN. By default, MSA firmware initially assigns ownership of all LUNs to the controller in slot
one (front-right) of the MSA. Then, based on access patterns and I/O load, the firmware
automatically re-assigns ownership of the LUN between the controllers to balance the load. If
your environment controls load balancing from the host, you must manually assign the preferred
path for each LUN.
Perform these tasks using your chosen configuration utility. Refer to the appropriate user
documentation for instructions.
Go to Table 13: ”Hard drive information” on page 112 and Table 14: ”Array (LUN) information” on
page 116 to record information about your storage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter and is the answer not in the manual?

HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter Specifications

General IconGeneral
BrandHP
Model353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter
CategoryDisk array system
LanguageEnglish

Related product manuals