Table 4 I/O module LEDs (continued)
IndicatesAppearanceLEDCallout
Off Not ready and no power
Flashing -- activity
Controller Node and Internal Component LEDs
Controller node LEDs are shown in Table 5 (page 22).
NOTE: Issue the locatenode command to flash the hotplug LED blue.
Table 5 Controller Node LEDs
No ClusterOnGreenStatus
BootQuick Flashing
Cluster memberSlow Flashing
OK to removeOnBlueHotplug
Not OK to removeOff
Locate command issuedFlashing
FaultOnAmberFault
No fautOff
Node in cluster and there is a
fault
Flashing
Ethernet LEDs
The controller node has two built-in Ethernet ports and each includes two LEDs (see Table 6 (page
22)).
Table 6 Ethernet LEDs
1 Gbe LinkOnGreenLink Up
Speed
Left
100 Mbit LinkOnAmber
No link established or 10 Mbit LinkOff
No link activityOnGreenActivityRight
No link establishedOff
Link activityFlashing
FC Port LEDs
The controller node has two FC ports and each includes two LEDs. The arrow heads shaped LEDs
point to the port they are associated with. The illustration shows the LEDs associated with the FC-1
port.: