Page #56 background image
Loss
of
Holding
Tone:
sign
in
right
display;
latching,
Count
Timer:
Nominally
5,15,
60
minutes,
or
nonstop.
Count
Range:
0
to
9999.
Max
Count
Rate:
Nominally
8
per
second.
Noise-to-Ground
(Receiver)
Transmitter:
off
and
terminated.
Range
(600,
900
and
1200
ohm):
50
to
130
dBm.
Resolution:
1
dB.
Accuracy:
±
1.5
dB
(60-130
dBrn);±
2.5
dB
(50-60
dBm).
Filters
and
Detector:
See
message
circuit
noise.
P/AR
Transmitter
Signal:
16
frequencies
in
range
140
to
3890
Hz.
Level
range:
-40
to
0
dBm.
Resolution:
1
dB.
Receiver
P/AR
Range:
0
to
120
units.
Resolution:
1
unit.
Accuracy
(30
to
110
units):
±
2
units.
Level
Range:
-40
to
+3
dBm
RMS
(135
and
160
ohm:
-30
to
+3
dBm
RMS).
Resolution:
1
dB.
General
Maximum
DC
Blocking:
200
V
nominal.
3-14
General
Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4934A and is the answer not in the manual?

HP 4934A Specifications

General IconGeneral
BrandHP
Model4934A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals