Hold
Circuit
WARNING
Hazardous
voltages
are
present
during
this
procedure
-
only
service
trained
personnel,
aware
of
the
hazards
involved,
should
perform
the
test.
EQUIPMENT
DC
Voltmeter
:
HP
3456A
DC
Power
Supply
:
HP
6234A
lOOQ
1%
Resistor
:HP
0757-0178
WECO
310
Connector
:
HP
1252-0695
PROCEDURE
1
Connect
the
equipment
as
shown
in
the
following
figure.
2
Set
the
HP
4934A
as
follows:
Measurement
Transmitter
(TRMT)
Impedance
Receiver
(RCV)
Impedance
Transmit
Hold
Select
Receive
Hold
Select
LEVEL
FREQ
600
n
6000
.
TRMT
HOLD
RCV
HOLD
Performance
Tests
5-11