41
Item
HP
5130-24G-4SF
P+ EI
HP
5130-24G-4SF
P+ EI BR
HP
5130-24G-2
SFP+-2XGT EI
HP
5130-48G-4SF
P+ EI
HP
5130-48G-4SF
P+ EI BR
HP
5130-24G-SF
P-4SFP+ EI
HP
5130-48G-2S
FP+-2XGT EI
100/1000B
ase-X SFP
ports
N/A N/A N/A
24 (The
rightmost eight
SFP ports and
their
corresponding
10/100/1000
Base-T
autosensing
Ethernet ports
form combo
interfaces.)
N/A
SFP+ ports 4 2 4 4 2
Power
supply slots
N/A N/A N/A
2, on the rear
panel
N/A
Input voltage
• Rated voltage: 100 VAC to 240
VAC @ 50 or 60 Hz
• Max voltage: 90 VAC to 264
VAC @ 47 to 63 Hz
• AC power source
Rated voltage: 100 VAC to 240 VAC @ 50 or 60
Hz
Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz
• DC power source: –48 V DC power source in the
equipment room or RPS (recommended HP RPS
models: A-RPS800 or A-R P S 1600 )
Rated voltage: –48 VDC to –60 VDC
• Max voltage: –36 VDC to –72 VDC
Minimum
power
consumption
19 W 20 W
• AC: 38 W
• DC: 38 W
• AC: 30 W
• DC: 38 W
• AC: 36 W
• DC: 36 W
Maximum
power
consumption
26 W 34 W
• AC: 45 W
• DC: 50 W
• AC: 60 W
• DC: 68 W
• AC: 54 W
• DC: 54 W
Chassis
leakage
current
compliance
• UL60950-1
• EN60950-1
• IEC60950-1
• GB4943.1
Melting
current of
power
supply fuse
AC-input: 2
A/250 V
2 A/250 V
• AC-input: 10
A/250 V
• DC-input: 5
A/250 V
• AC-input: 5
A/250 V
• DC-input: 8
A/250 V
• AC-input: 10
A/250 V
• DC-input: 5
A/250 V
Operating
temperature
0°C to 45°C (32°F to 113°F)
Operating
humidity
5% to 95%, noncondensing