HP
54501A
INSTALLATION
b
.
Use
strong
shipping
container
.
A
double-wall
carton
made
of
350
lb
.
test
material
is
adequate
.
c
.
Use
a
layer
of
shock-absorbing
material
70
to
100
mm
(3
to
4
inches)
thick
around
all
sides
of
instrument
to
firmly
cushion
and
prevent
movement
inside
the
container
.
Protect
control
panel
with
cardboard
.
d
.
Seal
shipping
container
securely
.
e
.
Mark
shipping
container
FRAGILE
to
ensure
careful
handling
.
f
.
In
any
correspondence,
refer
to
instrument
by
model
number
and
full
serial
number
.
2-9
.
PREPARATION
FOR
USE
2-10
.
Power
Requirements
The
HP
54501A
requires
a
power
source
of
either
115
or
230
Vac,
-22%
to
+10%
;
single
phase,
48
to
66
Hz
;
200
Watts
maximum
power
.
CAUTION
BEFORE
CONNECTING
POWER
TO
THIS
INSTRUMENT,
be
sure
the
line
voltage
switch
on
the
rear
panel
of
the
instrument
is
set
properly
and
the
cor-
rect
fuse
is
installed
.
2-11
.
Line
Voltage
Selection
Before
setting
instrument
power
switch
to
ON
position,
verify
that
the
fuse
module
is
in
the
correct
position
for
the
line
voltage
.
The
fuse
module
is
located
in
the
line
fil-
ter/power
switch
module
on
the
rear
panel
of
the
instrument
.
if
the
arrow
beside
the
voltage
on
the
fuse
module
that
is
in-line
with
the
filter
arrow
does
not
match
line
voltage
to
be
used,
it
must
be
changed
.
To
select
the
proper
fuse
for
line
2-2
voltage,
gently pry out
fuse
module
with
a
flat-blade
screwdriver
.
To
use
other
fuse
in
module,
turn
fuse
module
and
reinsert
into
the
line
filter
module
.
2-12
.
POWER
CABLE
WARNING
BEFORE
CONNECTING
THIS
INSTRUMENT,
the
protective
earth
terminal
of
the
instrument
must
be
connected
to
the
protective
conductor
of
the
(Mains)
power
cord
.
The
Mains
plug
must
be
inserted
in
a
socket
out-
let
provided
with
a
protective earth
contact
.
The
protective
action
must
not
be
negated
by
the,
use
of
an
exten-
sion
cord
(power
cable)
without a
protective
conductor
(grounding)
.
Grounding
one
conductor
of
a
two
conductor
outlet
does
not
provide
an
instrument
ground
.
This
instrument
is
provided
with
a
three-wire
power
cable
.
When
connected
to
an ap-
propriate
AC
power
outlet,
this
cable
grounds
the
instrument
cabinet
.
The
type
of
power
cable plug
shipped
with
the
instrument
depends
on
the
country
of
destination
.
Refer
to
figure 2-1 for
power
plugs
and
HP
part
numbers
for
the
available
plug
configurations
.
2-13
.
APPLYING
POWER
After
applying
power
to
the
HP
54501A,
an
in-
ternal
selftest
may
be
performed
by
following
the
procedure
in
section
3
.
If
the
message
"cal
ram
checksum
error
re-cal
instrument"
is
dis-
played
at
the
top
of
the
screen,
refer
to
HP
54501A
SELF
CALIBRATION
in
section
4
of
this
manual
.
2-14
.
CLEANING
REQUIREMENTS
Use
MILD
SOAP
AND
WATER
to
clean
the
HP
54501A
cabinet
and
front
panel
.
Care
must
be
taken
not
to
use
a
harsh
soap
which
will
damage
the
water-base
paint
finish
of
the
instrument
.