4-1
.
INTRODUCTION
This
section
provides
adjustment
and
self
calibration
procedures
for
the
HP
54501A
.
The
assemblies
with
adjustments
are
:
the
power
supply,
CRT
monitor,
and
the
systemboard
.
Figures
4-1
and
4-2
are the
testpoint
and
ad-
justment
locations
for
the
HP
54501A
.
4-2
.
EQUIPMENT
REQUIRED
Equipment
required
for
adjustments
is
listed
in
the
Recommended
Test
Equipment
table
in
section
1
of
this
manual
.
Any
equipment
that
satisfies
the
critical
specification
listed
in
the
table
may
be
substituted
for
the
recommended
model
.
4-3
.
CALIBRATION
INTERVAL
The
recommended
calibration
interval
for
the
HP
54501A
is
2000
hours
of
operation
(or
two
years,
whichever
comes
first)
.
The
adjust-
ments
are
set
at
the
factory
on
assemblies
when
they
are
tested
.
However,
adjustments
may
be
necessary
after
repairs
have
been
made
to
the
instrument
.
Usually
the
only
as-
sembly
that
may
require
adjustments
is
the
as-
sembly
that
has
been
replaced
.
4-4
.
HP
54501A
SELF
CALIBRATION
The
HP
54501A
has
self-contained
calibration
procedures
that
are
executed
after
manual
ad-
justments
have
been
made
to
the
System
Board
Assembly
.
The
self-calibration
routines
execute
automatic
A/D,
gain,
offset,
trigger,
and
delay
calibration
and
store
the
resulting
factors
to
non-volatile
memory
.
HP
54501A
ADJUSTMENTS
SECTION
4
ADJUSTMENTS
Default
values
from
system
ROM
are
loaded
to
non-volatile
memory
as
a
starting
reference
before
beginning
adjustments
on
the
System
Board
Assembly
.
When
power
is
applied
to
the
HP
54501
A
and
the
message
cal
ramchecksum
error
re-cal
in-
strument
is
displayed,
the
self
calibration
procedures
must
be
performed
.
Load
the
default
cal
factors
as
instructed
in
paragraph
4-12,
and
then
perform
the
self
calibration
in
paragraph
4-17
.
If
the
instrument
does
not
pass
the
self
calibra-
tion,
perform
all
of
the
adjustment
procedures
in
this
section
.
If
the
adjustments
cannot
be
made
within
the
specified
limits,
one
or
more
of
the
replaceable
modules
must
be
replaced
.
NOTE
An
instrument
warm-up
of
15
minutes
is
recommended
before
adjustment
procedures
are
performed
.
WARNING
Read
the
Safety
Summary
at
the
begin-
ning
of
this
manual
before
performing
any
adjustment
procedures
.
CAUTION
The
adjustment
procedures
are
perform-
ed
with
the
top
cover
of the
instrument
removed
.
Take
care
to
avoid
shorting
or
damaging
internal
parts
of
the instru-
ment
.