range.
When
the
laser
current
is
out
of
range,
the
laser
switches
off.
Bit
6
of
the
QUEStlonable:
power
node
summarizes
this
node.
The
QUEStionable:POWer:HCURRent
Node
This
node
gives
a
summary
of
the
laser
current
for
the
higher
wavelength
of
a
dual
wavelength
source.
Bit
0
returns
the
status
of
the
current
for
the
higher
wavelength
of
the
module
in
channel
A.
Bit
1
returns
the
status
of
the
current
for
the
higher
wavelength
of
the
module
in
channel
B.
A
1
means
that
the
laser
current
is
out
of
range
or
was
out
of
range.
When
the
laser
current
is
out
of
range,
the
laser
switches
off.
Bit
7
of
the
QUEStionabIe:POWer
node
summarizes
this
node.
The
QUEStionable:POWer:LMONitor
Node
This
node
gives
a
summary
of
the
laser
monitor
current.
For
a
dual
wavelength
source,
this
is
the
monitor
current
for
the
lower
wavelength
laser.
Bit
0
returns
the
status
of
the
monitor
current
for
the
module
in
channel
A.
Bit
1
returns
the
status
of
the
monitor
current
for
the
module
in
channel
B.
A
i
means
that
the
laser
monitor
current
is
currently
out
of
range
or
was
out
of
range.
This
node
is
summarized
bit
8
of
the
QUEStionable:POWer
node.
The
QUEStionable:POWer:HMONitor
Node
This
node
gives
a
summary
of
the
laser
monitor
current
for
the
higher
wavelength
of
a
dual
wavelength
source.
Bit
0
returns
the
status
of
the
monitor
current
for
the
higher
wavelength
of
the
module
in
channel
A.
Bit
1
returns
the
status
of
the
monitor
current
for
the
higher
wavelength
of
the
module
in
channel
B.
A
1
means
that
the
laser
monitor
current
is
currently
out
of
range
or
was
out
of
range.
When
the
laser
monitor
current
is
out
of
range,
the
laser
switches
off.
Bit
9
of
the
QUEStionable:POWer
node
summarizes
this
node.
The
QUEStionable:POWer:ENVTenip
Node
This
node
gives
a
summary
of
the
laser
environmental
temperature.
Bit
0
returns
the
status
of
the
environmental
temperature
of
the
module
in
channel
A.
Bit
I
returns
the
status
of
the
environmental
temperature
of
the
module
in
channel
B.
A
1
means
that
the
laser
environmental
temperature
is
currently
out
of
range
or
was
out
of
range.
When
the
laser
environmental
temperature
is
out
of
range,
the
laser
switches
off.
Bit
10
of
the
QUEStionable:POWer
node
summarizes
this
node.
7-18