Chapter 1 13
Installing Your Analyzer
STEP 4. Configure the Analyzer
5. If you will be using the serial port, adjust the analyzer's baud rate until it is equal to the
baud rate set on the peripheral by pressing PLOTTER BAUD RATE or PRINTER BAUD RATE and the
⇑ and ⇓ front panel keys. NOTE: The plotter menu is shown as an example. It will only
appear if you select PLOTTER PORT.
You can set the analyzer to the
following rates:
■ 1200
■ 2400
■ 4800
■ 9600
■ 19200
6. Also, if you will be using the serial port, you must set the transmission control XMIT CNTRL
(handshaking protocol) to either Xon/Xoff or DTR/DSR (equal to the transmission control set
on the peripheral). NOTE: Transmission control for plotters is set programmatically. The
plotter menu is shown as an example. It will only appear if you select PLOTTER PORT.
■ Xon/Xoff sets transmission
on/transmission off (software
handshake).
■
DTR/DSR sets data terminal
ready/data set ready (hardware
handshake).