EasyManuals Logo

HP C2488A User Manual

HP C2488A
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
Error
Code
Hex(Dec)
2A(42)
2B(43)
2C(44)
20(45)
2E(46)
2F(47)
thru
31(49}
32(50)
33(51)
34(52}
35(53)
36(54)
37(55)
38(56)
39(57)
3A(58)
3B(59)
3C(60)
30(61)
3E(62)
3F(63)
40(64)
41(65)
42(66)
43(67)
44(68)
45(69)
46(70)
47(71)
48(72)
49(73)
4A(74)
4B(75)
4C(76)
40(77)
4E(78)
4F(79)
thru
1F(127)
Table
C-1.
Vendor
Unique
DERROR
Status
Codes
(continued)
Description
HDA
EEPROM
test
byte
is
not
55H.
HDA
EEPROM
checksum
result
not
equal
to
00.
PCA
EEPROM
test
byte
is
not
55H.
PCA
EEPROM
checksum
result
not
equal
to
00.
Computed
read/write
setting
is
Gut
of
range.
Reserved.
The
long
term
DSP
command
completed
with
Alert signal
set
in
status
register.
The
DSP
Alert signal was
set
when
attempting
to
send
a
command
to
the
OSP.
Request
Status
logged a Servo
Fault
from
the
fault register.
DSP
failure code
indicates
other
than
Reset
at
power-on.
Reserved.
Reserved.
Maximum
DC
head
alignment
correction
capability
was exceeded.
Maximum
AC
head
alignment
correction
capability
was exceeded.
Maximum
iteration
limit
was exceeded
in
calibrating
the
NPES
gain.
SPES
gain
not
within
acceptable
level.
Reserved.
Reserved.
Write
current
unsafe.
Command
requires a special
test
enable
to
be
executed.
Unknown
write fault.
Write
during
loss
of
servo
timing
sync.
Write
during
momentary
spindle
off-speed indication.
Write
during
momentary
actuator
off-track
indication.
Write
during
a seek
operation.
Write
after
settle
or
tracking
failure.
Write
following aggressive
settle.
Not
defined.
Write
was
attempted
while
ESDI
attention
was
asserted.
Write
was
attempted
while
an
illegal
head
was selected.
Write
was
attempted
while a
recalibrate
was
in
process.
Write
was
attempted
on
a
head
that
was
in
the
head
alignment
critical
state.
Write
was
attempted
while a
head
alignment
was
in
process.
Write
was
attempted
after
a
fatal
head
alignment
occurred.
Write
was
attempted
while
spun
down
or
after
a
recalibrate
failure.
Reserved.
C-2
Vendor
Unique
Status
Codes
DRAFT
1/18/93 09:58

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP C2488A and is the answer not in the manual?

HP C2488A Specifications

General IconGeneral
BrandHP
ModelC2488A
CategoryStorage
LanguageEnglish

Related product manuals