8Ć28 Troubleshooting
C4699Ć90000
EEROM Model ID Configuration Procedure for the DesignJet 330
and 350C
The EEROM model ID configuration procedure only needs to be carried out if:
D A preĆconfigured board is being reused.
D The current board is incorrectly configured to the wrong model ID.
D The plotter shows an unconfigured model ID system error ( ).
It is very rare that these situations will ever occur.
Configure the plotter model ID as follows:
Remove the left cover ' page 6Ć10.
Disconnect the media motor encoder cable from the main PCA (connector ENC X).
Turn the plotter ON in Service Mode .
Hold the key down and press the key.
Once in Deconfiguration Mode, the first and second LED
columns should light up.
Using a suitable tool, shortĆcircuit pins 1 and 2 (the first two
pins on the right) of the media motor encoder connector (ENC X).
The second and third LED columns should light up as you
shortĆciruit the two pins.
Once you have shortĆcircuited the two pins, the first and
second LED columns should light up again.
Press the
Shift key to exit the Deconfiguration Mode.
Deconfiguration
Mode
ALT
Shift