3 
 
●  Do not get the board wet. Water and moisture can cause a short circuit that causes malfunctions. 
●  To avoid damage, be sure to use lead-free solder. 
●  When soldering, work quickly to avoid overheating the circuit board. 
●  Keep the soldering iron tip clean and well tinned when replacing parts. 
●  After repair, perform a close inspection of the circuit board to confirm it is in good condition. 
●  After repair, perform a function test to confirm the power supply is working properly. 
ERP Lot5 requirement 
1. A professional repairer must have the technical competence to repair electronic displays and comply with 
the applicable regulations for repairers of electrical equipment in the Member States where the repairer 
operates. Reference to an official registration system as professional repairer, where such a system exists in the 
Member States, shall be accepted as proof of compliance. 
2. A professional repairer must have insurance that covers liabilities resulting from repairs, regardless of 
whether required by the Member State. 
RoHS (2002/95/EC) requirements 
Applied to all countries that require RoHS.  
The RoHS (Restriction of Hazardous Substance in Electrical and Electronic Equipment Directive) is a legal 
requirement by the EU (European Union) for the global electronics industry sold in the EU and other countries. 
Any electrical and electronics products launched in the market after June 2006 should meet this RoHS 
requirement. Products launched in the market before June 2006 are not required to be compliant with RoHS parts. 
If the original parts are not RoHS complaint, the replacement parts can be non-ROHS complaint. If the original 
parts are RoHS compliant, the replacement parts MUST be RoHS complaint. 
If product service or maintenance requires replacing parts, confirm the RoHS requirement before replacement. 
General descriptions 
This manual contains general information. There are two levels of service: 
Level 1: Cosmetic/appearance/alignment service 
Level 2: Circuit board or standard parts replacement 
Firmware updates 
Firmware updates for the monitor are available at support.hp.com. If no firmware is posted, the monitor does not 
need a firmware update. 
Before returning the repaired product to the customer 
Perform an AC leakage current check on exposed metallic parts to be sure the product is safe to operate without 
the potential of electrical shock. Do not use a line isolation transformer during this check. 
Measurements that are not within specified limits present a possible shock hazard. You must check and repair the 
product before returning it to the customer.