Example 4-2 Sample Link Aggregate 64-Bit Statistics
# nwmgr --st -I 901 -S apa
*** lan901 64 bit MIB statistics:
Interface Name = lan901
PPA Number = 901
Description = lan901 Hewlett-Packard LinkAggregate Interface
MTU Size = 1500
Speed = 3 Gbps
Station Address = 0x0012794371B4
Administration Status = UP
Operation Status = UP
Last Change = Thu Sep 28 18:35:11 2006
Inbound Octets = 1353732
Inbound Unicast Packets = 0
Inbound Multicast Packets = 0
Inbound Broadcast Packets = 0
Inbound Discards = 0
Inbound Errors = 0
Inbound Unknown Protocols = 22064
Outbound Octets = 0
Outbound Unicast Packets = 0
Outbound Multicast Packets = 0
Outbound Broadcast Packets = 0
Outbound Discards = 0
Outbound Errors = 0
Counter Discontinuity Time = Thu Sep 28 18:35:10 2006
Physical Promiscuous Mode = FALSE
Physical Connector Present = FALSE
Interface Alias =
Link Up/Down Trap Enable = Enabled
Monitoring HP APA statistics
For the December 2007 release (B.11.31.10) and later of HP APA for HP-UX 11i v3, the nwmgr
command --stats monitor option enables you to view APA traffic continuously, including
statistics of every member port of an APA link aggregate. You can specify the following
parameters:
-q counter=type The counter parameter can have the following values:
o Displays octet counters. You cannot specify this value with p
or t.
p Displays packet counters. You cannot specify this value with o
or t.
t
Displays throughput counters in Mb/s. You cannot specify this
value with o or p.
y
Displays physical errors.
If you do not specify this parameter, packet counters are displayed.
-q value=value The value parameter can have the following values:
c
Displays current counters. You cannot specify this value with
d or r.
d
Displays the difference between the previous counter value and
the current value. You cannot specify this value with c or r.
r
Uses the counter values in the first iteration as a base (0) and
displays the counters incremented from the base. You cannot
specify this value with c or d.
If you do not specify this parameter, current counter values are
displayed.