152
Software Fixes in Release M.08.51 - M.10.72
Release M.08.75
Release M.08.75
Problems Resolved in Release M.08.75
LR optic (PR_1000282195) — After a switch reboot, certain 10GbE X2-SC LR Optic
(J8437A) transceivers will lose its configuration. Administrator will be unable to turn off
LACP, and CLI commands will not be displayed.
XRRP (PR_1000280213) — When configuring a XRRP instance, although the subnet is
configured properly, the following error message is logged:
No subnet configured for the IP address
Release M.08.76
Problems Resolved in Release M.08.76 (Never released)
IP Routing (PR_1000254254) — L3 address table is not learned correctly from unsolicited
ARPs.
RADIUS (PR_1000285456) — If more than one RADIUS assigned vendor specific attribute
(including Port-cos, rate-limiting-ingress, or ACLs) is configured with a non-vendor specific
attribute, only the first vendor specific attribute may be recognized by the switch.
TCP (PR_1000246186) — Switch is susceptible to VU#498440.
VLAN (PR_1000214406) — When trying to delete a VLAN created as a management VLAN,
the switch fails to remove the management VLAN statement from the running configuration
file.
Web UI (PR_1000284653) — When using the web user interface "IP Stack Management", and there
are more than 100 potential Members present on a VLAN, the Switch will learn new potential
Members, but deletes previously learned Members.
Release M.08.77
Problems Resolved in Release M.08.77 (Not a general release)
ACL (PR_1000283338) — The commands "show port-access mac" and "show port-
access web" incorrectly display the number of clients authenticated.
Meshing (PR_1000219337) — Unstable RSTP topology when root switch is power-cycled