EasyManua.ls Logo

HP ProCurve Series 3400cl

HP ProCurve Series 3400cl
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
168
Software Fixes in Release M.08.51 - M.10.72
Release M.10.28
Release M.10.28
Problems Resolved in Release M.10.28 (Not a general release)
CLI/LLDP (PR_1000377191) — Output from the CLI command, "show lldp info remote-
device <port>" shows a blank field for the chassis ID.
CLI (PR_1000390970) — The command "tftp-enable" is removed from the CLI since that
functionality is served by "tftp server|client".
CLI/Counters (PR_1000379222) — Jumbo sized frames received on 10GbE ports decre-
ment the "Total Rx Errors" counters. The 32 bit counter rolls from 0 backwards to 4,294,967,295
and continues to decrement with each received Jumbo frame.
Trunking (PR_1000238829) — Trunks numbered trk10 and greater cause the output from
the CLI command "show span" output to be misaligned.
Release M.10.29
Problems Resolved in Release M.10.29 (Never released)
CLI/Config (PR_1000375830) — When using the "no VLAN" command, the user is asked
if they want to remove the VLAN. Answering "no" will result in the VLAN being removed
anyway.
CLI/config (PR_1000391119) — Copying a configuration file to a switch with a BPDU
protection timeout value set may produce an error similar to:
CCCCCline: 10007. 1200: Error setting configuration
CLI (PR_1000390385) — The CLI help text for "span bpdu-protection-timeout" is incorrect;
it erroneously displays the help text for "span hello-time."
Enhancement (PR_1000376626) — Enhance CLI "qos dscp-map he" help and "show dscp-
map" text to warn the user that inbound classification based on DSCP codepoints only occurs
if "qos type-of-service diff-services" is also configured.
Lockup (PR_1000394749) — Switch may lockup when a certain J4858A transceiver type
is inserted.
SNMP (PR_1000392847) — RMON alarms that monitor port-specific OIDs are lost if the
switch is rebooted.
Traceroute (PR_1000379199) — The reported "traceroute" time is inaccurate; it is one
decimal place off.

Table of Contents