82
Enhancements
Release M.10.09 Enhancements
Configuration Considerations
UDLD is configured on a per-port basis and must be enabled at both ends of the link. See the
note below for a list of ProCurve switches that support UDLD.
To configure UDLD on a trunk group, you must configure the feature on each port of the
group individually. Configuring UDLD on a trunk group’s primary port enables the feature
on that port only.
Dynamic trunking is not supported. If you want to configure a trunk group that contains
ports on which UDLD is enabled, you must remove the UDLD configuration from the ports.
After you create the trunk group, you can re-add the UDLD configuration.
Note
UDLD interoperates with the following ProCurve switch series: 2600, 2800, 3400, 3500, 4200, 5300,
5400, 6200, 6400, and 9300. Consult the release notes and current manuals for required software
versions.
Configuring UDLD
The following commands allow you to configure UDLD via the CLI.
Syntax: [no] interface <port-list> link-keepalive
Enables UDLD on a port or range of ports.
To disable the feature, enter the no form of the command.
Default: UDLD disabled
Syntax: link-keepalive interval <interval>
Determines the time interval to send UDLD control packets. The <interval> param-
eter specifies how often the ports send a UDLD packet. You can specify from 10 –
100, in 100 ms increments, where 10 is 1 second, 11 is 1.1 seconds, and so on.
Default: 50 (5 seconds)
Syntax: link-keepalive retries <num>
Determines the maximum number of retries to send UDLD control packets. The
<num> parameter specifies the maximum number of times the port will try the health
check. You can specify a value from 3 – 10.
Default: 5
Syntax: [no] interface <port-list> link-keepalive vlan <vid>
Assigns a VLAN ID to a UDLD-enabled port for sending of tagged UDLD control
packets.Under default settings, untagged UDLD packets can still be transmitted and
received on tagged only ports—however, a warning message will be logged.
The no form of the command disables UDLD on the specified port(s).
Default: UDLD packets are untagged; tagged only ports will transmit and receive
untagged UDLD control packets

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve Series 3400cl and is the answer not in the manual?

HP ProCurve Series 3400cl Specifications

General IconGeneral
BrandHP
ModelProCurve Series 3400cl
CategorySwitch
LanguageEnglish

Related product manuals